Sale!
,

1756-L74 ALLEN BRADLEY

Original price was: $2,530.00.Current price is: $1,923.00.

The Allen-Bradley 1756-L74 is a 5570 ControlLogix Programmable Automation Controller (PAC). This controller features 16 MB user memory, I/O memory of 0.98 MB and 1 GB non-volatile memory via the 1784-SD1 that ships with the controller. It has 1 USB communication port and supports interfacing of up to 128,000 Discrete I/O and 4000 Analog I/O memory.
GTIN: 10612598876041 SKU: 1756-L74 Categories: ,

1756-L74 ALLEN BRADLEY

Technical specifications for 1756-L74

Manufacturer Rockwell Automation
Maximum Analog I-O 4000
Maximum I-O 128000
Module Type Processor Module
Series ControlLogix
Part Number/Catalog No. 1756-L74
Brand Allen-Bradley
Product Type Programmable Automation Controller
Non-volatile memory 1GB (ships with the controlelr)
No. of task 32
Programs per task 100 Programs
Event Task All Triggers
Built-in communication 1 USB port
Optional Communication adapters • EtherNet/IP • ControlNet • DeviceNet • Data Highway Plus • Remote I/O • SynchLink • Third-party process and device networks
Redundancy Full Support
Integrated Motion • SERCOS interface • Analog options (encoder input, LDT input, SSI input) • Integrated Motion on the EtherNet/IP network
I-O Memory 0.98 MB
User Memory 16 MB
Maximum Digital I-O 128,000
Current Draw (1.2 Volts DC) 5 milliamps
Current Draw (5.1 Volts) 800 milliamps
Power Dissipation 2.5 Watts
Thermal Dissipation 8.5 BTU per hour
Isolation Voltage 30 Volts Continuous
Enclosure None
UPC 10612598876041
Description

The Allen-Bradley 1756-L74 is a Programmable Automation Controller (PAC) that is used for implementing factory and process automation requirements. This controller has a modern design that is specifically catered to meet the requirements of today’s industrial automation requirements.

The 1756-L74 is a single slot width controller, designed with a compact and assembly. It is a chassis-based device that is powered internally by the backplane power distributed to the chassis’ electronic circuitry. This controller is compatible for installation in all of the available chassis made for the ControlLogix system such as 1756-A4, 1756-A4K, 1756-A7, 1756-A7K, 1756-A10, 1756-A10K, 1756-A13, 1756-A13K,1756-A17, 1756-A17 K.

The 1756-L74 is an environment-friendly controller, as it utilizes energy storage module instead of batteries for keeping the contents of the Random Access Memory (RAM). Energy storage modules are capacitor based which means RAM memory is retained by the energy stored within the capacitors. These energy storage modules are removable and replaceable. For this controller, a 1756-ESMCAP is pre-installed while other compatible modules include 1756-ESMNSE, 1756-ESMNSEK, 1756-ESMNRM, and 1756-ESMNRMK.

The 1756-L74 comes with a 16MB user memory, 0.98 MB I/O memory and ships with a 1GB non-volatile memory via the 1784-SD1. The non-volatile memory may be expanded up to 2GB by replacing the existing unit the 1784-SD2, 2 GB Secure Digital (SD) card.

The 1756-L74 communicates via the built-in USB communication port, however, this port is not ideal for industrial communication. For the mentioned purpose, user may install additional communication adapters that supports specific communication protocols such as EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, SynchLink and Third-party process and device networks.

It is also compatible communicating through EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, and SynchLink. Its integrated motion features are SERCOS interface, analog options, and integrated motion on the EtherNet/IP network. The programming languages are relay ladder, structured text, function diagram, and sequential function chart.

The 1756-L74 controller has a 16 MB user memory and a 0.98 MB I/O memory. It has 128,000 total and digital I/O and 4000 analog I/O. The controller has compatible energy storage modules like the 1756-ESMCAP, 1756-ESMCAPK, 1756-ESMNSE, 1756-ESMNSEK, 1756-ESMNRM, and the 1756-ESMNRMK modules. The 1756-L74 controller only requires 2.5 W of power dissipation and only 8.5 BTU/hr of thermal dissipation. It has a USB port-to-system basic insulation type. It has a chassis-based module location at any slot for the 1756 series with a 1-slot width. Possible chassis include the 1756-A4, 1756-A4K, 1756-A7, 1756-A7K, 1756-A10, 1756-A10K, 1756-A13, 1756-A13K,1756-A17, and the 1756-A17 K. The 1756-L74 uses a standard power supply such as the 1756-PA50, 1756-PA72, and the 1756-PA72K. For power supply redundancy, it only uses the 1756-PA75R, 1756-PA75RK, 1756-PB75R, 1756-PB75RK, 1756-PSCA2, or the 1756-PSCA2K. The 1756-L74 has an open-style enclosure, an operating temperature of 0-60°C, and a non-operating temperature of -40 – 85°C. Its operating vibration is 10g at 500 Hz at 2 g, its operating shock is 30 g, and its non-operating shock is 50 g.

Revisions

Revision Part # Also known as
1756-L74 Ser A 1756-L74/A, Series A, Rev A
1756-L74 Ser B 1756-L74/B, Series B, Rev B

Alternative names

  • 1756-174
  • 1756-L7A
  • 1756174
  • 1756L74
  • 1756L7A
  • L756-17A
  • L756-L74
  • L75617A
  • L756L74

Repairs

Frequently asked questions

Does the 1756-L74 support controller redundancy?

Yes. The 1756-L74 has full support for controller redundancy.

How many slot does the 1756-L74 occupy?

The 1756-L74 only occupies single chassis slot.

Does the controller utilizes battery for retaining the contents of the RAM?

No. The 1756-L74 utilizes energy storage module which are capacitor based rather than batteries.

Technical notes

Allen Bradley ControlLogix Processor Module with 0.98 MB I-O Memory and 16 MB User Memory

Documentation

RESOURCE PUBLICATION NUMBER
Technical Data 1756-TD001
User Manual 1756-UM001
Weight 2.9 kg
Dimensions 18 × 26 × 31 cm
Shopping Cart
1756-L741756-L74 ALLEN BRADLEY
Original price was: $2,530.00.Current price is: $1,923.00.